SR 300 to 3000 Watts series

Voltage: from 300 Volts to 200.000 Volts
Power: from 300 Watts to 3.000 Watts
Size (rack - depth): 3U - 480 mm / 3U - 600mm / 5U - 600mm

Applications (examples): Burn-in and dielectric tests, Molecular Beam Epitaxy (MBE), electrostatic application, leakage testing, DC plasma application

download datasheet request a quote button

rack 3 U

SR 20KV-1.2KW 0 to 20 kV, 1200W
Non-contractual photo

Overview


  • Compact & industrial design
  • Low stored energy
  • Voltage & current outputs continuously adjustable from 0 to 100%
  • Voltage & current setting & monitoring from front panel or remote interface
  • Customized voltage & current* with no extra cost
  • High reliability & efficiency
  • High precision regulation
  • Total protection against arc, overload, short circuit & over temperature
  • Automatic regulation crossover
  • Over current limitation
  • Remote, inhibit & interlock functions
  • 3 ½ digit display with polarity display
  • Double resonance technology (ZVC)
  • Safety switch key
  • Air cooling
  • 2 years warranty

Front panel

front panel 3 U rack

Rear panel

rear panel 3 U rack

* You can choose your own full scales (Vmax and Imax) even if these values are not available in standard. For example, you can get a 3750 V generator based on 1.5 kW model. In this case, you will get an output voltage adjustable from 0 to 3750 V and an output current from 0 to 0.4A.

Description

The numerous advantages of compactness, robustness, reliability, and saving offered with the double resonance technology are already available on these models which constitute the low end range.

Five series of power are offered: 300W, 600W, 1,2kW, 1,5kW and 3kW.
These products are all based on a 3U and 5U height 19’’ rack presentation.
Using a modular design, our products integrate the latest technology components.
Above 20KV, HV stages are in resin.

Options


  • Reversibility and floating outputs
  • Non instrumented front panel
  • Power regulation
  • Arc detection and counting
  • RS232, GPIB, Ethernet and Profibus interfaces
  • Optic fiber transmission kit with RS232 only
  • LABVIEW run time RS232 or GPIB or Ethernet
  • Relay interface 24V DC
  • Insulated remote interface
  • Customer remote adaptation
  • Emergency stop switch

 

  • Adaptation customer to remote interface
  • Single or multichannel control unit
  • Safety signs and devices alerting to hazard
  • 10ms settling time
  • Zero floating
  • Adjustable rise time
  • Tropicalization
  • Transportable “all terrain” container
  • Specific AC or DC mains power inputs
  • OEM Design on request
  • Remote front panel

Any special requests can be considered

Possible restrictions when multiple options (please contact our sales department for more details or check our compatibility matrix)
contact us button or
Compatibility matrix

Electrical specifications


Output Voltage and Output Current
Both Voltage Output and Current Output are continuously adjustable
from 0 to 100 % (full scale)
In local mode: by using 10 turns potentiometers resolution 0.05%
In remote mode: by an external 0 to 10 V

Voltage regulation*
Load Regulation: ± 0.05 % of full voltage (for 0 – 100% load)
± 0.01 % available on request
Line Regulation: ± 0.01 % of full load ( for Mains Voltage ± 10 %)
± 0.01 % available on request

Current regulation *
Load Regulation: ± 0.05 % of full current  (for 0 – 100 % load)
Line Regulation: ± 0.05 % of full load (for Mains Voltage ± 10 %)

Ripple + Noise : 0.1% RMS of full voltage

Settling time
100 ms typical for output voltage ≤ 100 kV**, 10 ms available on request

Protections
Against short circuit & HV arc to ground
Shutdown on over temperature & open interlock

Stored energy: 1 J/ kW

Stability (after one hour warm-up)
0.01 % / hour, 0.03 % / 8 hours of operating with constant load and ambient temperature

Temperature Coefficient: 100 ppm/°C

Operating Temperature: from 0 to 40°C

Efficiency: > 90 % full load

Air Cooling by air
Dust filter fans on front panel
Easily removable filters for cleaning

Mains Voltage
Up to 1,2 kW: 170V to 255 VAC 47 - 63 Hz Single Phase + Earth
Power factor correction Input ≥0.98
From 1,5 kW: 400 VAC ±10% 47 – 63 Hz 3 Phases + Earth
Power factor: ≥0.98

Inrush current: limited to full power operating current

Calibration: with probes periodically approved by Authorized Measurement Laboratories

CE Certification


* For fixed polarity
** 300 ms typical for output voltage ≥120kV

Physical description


SR 300W Series SR 600W Series SR 1.2KW Series SR 1.5KW Series SR 3KW Series
Voltage Current Model Current Model Current Model Current Model Current Model
300 V NOT AVAILABLE 5.0 A SR300V-1.5KW 10.0 A SR300V-3KW
700 V 429 mA SR700V-300W 857 mA SR700V-600W 1.71 A SR700V-1.2KW 2.14 A SR700-1.5KW 4.29 A SR700V-3KW
1 kV 300 mA SR1KV-300W 600 mA SR1KV-600W 1.2 A SR1KV-1.2KW 1.50 A SR1KV-1.5KW 3.00 A SR1KV-300W0
2.5 kV 120 mA SR2.5KV-300W 240 mA SR2.5KV-600W 480 mA SR2.5KV-1.2KW 600 mA SR2.5KV-1.5KW 1.20 A SR2.5KV-3KW
5 kV 60.0 mA SR5KV-300W 120 mA SR5KV-600W 240 mA SR5KV-1.2KW 300 mA SR5KV-1.5KW 600 mA SR5KV-3KW
10 kV 30.0 mA SR10KV-300W 60.0 mA SR10KV-600W 120 mA SR10KV-1.2KW 150 mA SR10KV-1.5KW 300 mA SR10KV-3KW
15 kV 20.0 mA SR15KV-300W 40.0 mA SR15KV-600W 80.0 mA SR15KV-1.2KW 100 mA SR15KV-1.5KW 200 mA SR15KV-3KW
20 kV 15.0 mA SR20KV-300W 30.0 mA SR20KV-600W 60.0 mA SR20KV-1.2KW 75.0 mA SR20KV-1.5KW 150 mA SR20KV-3KW
30 kV 10.0 mA SR30KV-300W 20.0 mA SR30KV-600W 40.0 mA SR30KV-1.2KW 50.0 mA SR30KV-1.5KW 100 mA SR30KV-3KW
40 kV 7.50 mA SR40KV-300W 15.0 mA SR40KV-600W 30.0 mA SR40KV-1.2KW 37.5 mA SR40KV-1.5KW NOT AVAILABLE
50 kV 6.00 mA SR50KV-300W 12.0 mA SR50KV-600W 24.0 mA SR50KV-1.2KW 30.0 mA SR50KV-1.5KW
60 kV 5.00 mA SR60KV-300W 10.0 mA SR60KV-600W 20.0 mA SR60KV-1.2KW 25.0 mA SR60KV-1.5KW
80 kV 3.75 mA SR80KV-300W 7.50 mA SR80KV-600W 15.0 mA SR80KV-1.2KW 18.7 mA SR80KV-1.5KW
100 kV 3.00 mA SR100KV-300W 6.00 mA SR100KV-600W 12.0 mA SR100KV-1.2KW ON REQUEST
120 kV 2.50 mA SR120KV-300W 5.00 mA SR120KV-600W 10.0 mA SR120KV-1.2KW
150 kV 2.00 mA SR150KV-300W 4.00 mA SR150KV-600W 8.0 mA SR150KV-1.2KW
200 kV 1.50 mA SR200KV-300W 3.00mA SR200KV-600W 6.0 mA SR200KV-1.2KW

For other/higher voltage, please contact us button


Polarity can be positive, negative, floating (option) or reversible (option)
Floating or reversibility options can modify the size of the unit
 
rack 3 U rack 5 U
Example of reference : SR 15KV-300W
Model: SR model (generator)
Voltage: Adjustable from 0 to 15 kV
Power: 300 W
3U - 19" rack
H133xW483xD480 mm
H133xW483xD600 mm
5U - 19" rack
H222xW483xD600