SR 5 000 to 10 000 Watts series

Voltage: from 300 Volts to 150 000 Volts
Power: from 5 000 Watts to 10 000 Watts
Size (rack - depth): 5U - 480 mm / 5U - 600 mm / 7U - 600 mm / 19" cabinet - 800 mm

Applications (examples): Ion sources, DC magnetrons sputtering, Semi-conductor manufacturing equipment, Pulse Forming Networks (PFN), X-Ray systems supplies

download datasheet request a quote button

rack 5 U

SR 16KV-10KW 0 to 16 kV, 0 to 625 mA
Non-contractual photo

Overview

  • Compact & industrial design
  • Low stored energy
  • Low cost per Watt
  • Voltage & current outputs continuously adjustable from 0 to 100%
  • Voltage & current setting & monitoring from front panel or remote interface
  • Customized Voltage & Current* with no extra cost
  • High reliability & efficiency
  • High precision regulation
  • Total protection against arc, overload, short circuit & over temperature
  • Automatic regulation crossover
  • Over current limitation
  • Remote, inhibit & interlock functions
  • 3 ½ digit display with polarity display
  • Double resonance technology (ZVC)
  • Safety switch key
  • Air cooling
  • 2 years warranty

Front panel

front panel 5 U rack

Rear panel

rear panel 5 U rack

* You can choose your own full scales (Vmax and Imax) even if these values are not available in standard. For example, you can get a 45kV generator based on 6 kW model. In this case, you will get an output voltage adjustable from 0 to 45kV and an output current from 0 to 1.33A.

Description

Double resonance technology operating at high frequency (40 kHz) improves reliability by a smooth switching of the critical components.
In addition, internal power dissipation, harmonics & ripples are significantly reduced.
Hence, our generators can intensively operate with no failure even in rugged environments. Many of them are used at full power 24 hours per day, 7days per week.

4 series of power are offered from 5kW to 10kW.
Above 20KV, HV stages are in oil.
With its low cost per Watt, this series is particularly well adapted in applications looking for power and performance at affordable prices.

Options

  • Reversibility and floating outputs
  • Non instrumented front panel
  • Power regulation
  • Arc detection and counting
  • RS232, GPIB, Ethernet and Profibus interfaces
  • Optic fiber transmission kit with RS232 only
  • LABVIEW run time RS232 or GPIB or Ethernet
  • Relay interface 24V DC
  • Insulated remote interface
  • Emergency stop switch
  • industrial dust filters

 

  • Adaptation customer to remote interface
  • Multichannel control unit: up to 6 generators
  • Safety signs and devices alerting to hazard
  • 10ms settling time
  • Zero floating
  • Adjustable rise time
  • Tropicalization
  • Transportable “all terrain” container
  • Specific AC or DC mains power inputs
  • OEM Design on request
  • Remote front panel

Any special requests can be considered

Possible restrictions when multiple options (please contact our sales department for more details or check our compatibility matrix)
contact us button or
Compatibility matrix

Electrical specifications

Output Voltage and Output Current
Both Voltage Output and Current Output are continuously adjustable
from 0 to 100 % (full scale)
In local mode: by using 10 turns potentiometers resolution 0.05%
In remote mode: by an external 0 to 10 V

Voltage regulation *
Load Regulation: ± 0.05 % of full voltage (for 0 – 100% load)
± 0.01 % available on request
Line Regulation: ± 0.01 % of full load ( for Mains Voltage ± 10 %)
± 0.01 % available on request

Current regulation *
Load Regulation: ± 0.05 % of full current  (for 0 – 100 % load)
Line Regulation: ± 0.05 % of full load (for Mains Voltage ± 10 %)

Ripple + Noise : 0.1% RMS of full voltage for 3 phases models

Settling time
100 ms typical for output voltage ≤ 100 kV**, 10 ms available on request

Protections
Against short circuits & HV arc to ground
Shutdown on over temperature & open interlock

Stored energy: 1 J/ kW

Stability (after one hour warm-up)
0.01 % / hour, 0.03 % / 8 hours of operating with constant load and ambient temperature

Temperature Coefficient: 100 ppm/°C

Operating Temperature: from 0 to 40°C

Efficiency: > 90 % full load

Recoverytime after arc: < 1 ms

Air Cooling by air
Dust filter fans on front panel
Easily removable filters for cleaning

Mains Voltage: 400 VAC ±10% 47 – 63 Hz 3 Phases +Earth
Power factor : > 0.98

Inrush current: limited to full power operating current

Calibration: with probes periodically approved by Authorized Measurement Laboratories

CE Certification


* For fixed polarity
** 300 ms typical for output voltage ≥120kV

Physical description

  SR 5kW Series SR 6kW Series SR 8kW Series SR 10kW Series
Voltage Current Model Current Model Current Model Current Model
300 V 16.67 A SR300V-5KW 20.00 A SR300V-6KW 26.67 A SR300V-8KW 33.33 A SR300V-10KW
700 V 7.14 A SR700V-5KW 8.57 A SR700V-6KW 11.43 A SR700V-8KW 14.29 A SR700V-10KW
1 kV 5.00 A SR1KV-5KW 6.00 A SR1KV-6KW 8.00 A SR1KV-8KW 10.00 A SR1KV-10KW
2.5 kV 2.00 A SR2.5KV-5KW 2.40 A SR2.5KV-6KW 3.20 A SR2.5KV-8KW 4.00 A SR2.5KV-10KW
5 kV 1.00 A SR5KV-5KW 1.20 A SR5KV-6KW 1.60 A SR5KV-8KW 2.00 A SR5KV-10KW
10 kV 500 mA SR10KV-5KW 600 mA SR10KV-6KW 800 mA SR10KV-8KW 1.00 A SR10KV-10KW
15 kV 333 mA SR15KV-5KW 400 mA SR15KV-6KW 533 mA SR15KV-8KW 667 mA SR15KV-10KW
20 kV 250 mA SR20KV-5KW 300 mA SR20KV-6KW 400 mA SR20KV-8KW 500 mA SR20KV-10KW
30 kV 167 mA SR30KV-5KW 200 mA SR30KV-6KW 267 mA SR30KV-8KW 333 mA SR30KV-10KW
40 kV 125 mA SR40KV-5KW 150 mA SR40KV-6KW 200 mA SR40KV-8KW 250 mA SR40KV-10KW
50 kV 100 mA SR50KV-5KW 120 mA SR50KV-6KW 160 mA SR50KV-8KW 200 mA SR50KV-10KW
60 kV 83.3 mA SR60KV-5KW 100 mA SR60KV-6KW 133 mA SR60KV-8KW 167 mA SR60KV-10KW
80 kV 62.5 mA SR80KV-5KW 75 mA SR80KV-6KW 100 mA SR80KV-8KW 125 mA SR80KV-10KW
100 kV 50 mA SR100KV-5KW 60 mA SR100KV-6KW 80 mA SR100KV-8KW 100 mA SR100KV-10KW
120 kV 40 mA SR120KV-5KW 50 mA SR120KV-6KW 66.7 mA SR120KV-8KW 83.3 mA SR120KV-10KW
150 kV ON REQUEST
200 kV

For other/higher voltage, please contact us button

Polarity can be positive, negative, floating (option) or reversible (option)
Floating or reversibility options can modify the size of the unit
rack 5 U rack 7 U cabinet
Example of reference : SR 40KV-6KW
Model: SR model (generator)
Voltage: Adjustable from 0 to 40 kV
Power: 6 kW
5U - 19" rack
H222xW483xD480 mm
H222xW483xD600 mm
7U - 19" rack
H311xW483xD600 mm
cabinet - 19" rack
Height from 12 to 30HU ; Depth 800mm