Applications (examples): Klystron; Pulsed Electric Field (PEF), RF power systems; ion implantation, Non Destructive Testing (NDT) systems, X-Ray power supplies systems, Cyclotron
Download Data Sheet Request a quote
With more than 10 years of experience in design and production of electron beam welding, TECHNIX offers a complete range of sources dedicated for this application.
Based on double-resonance technology, these power supplies offer many advantages in terms of performance, flexibility, reliability and price.
Integrated models are offered for customers for customers who are looking for a plug and play configuration.
All the models include an oil tank.
In standard 45 kV, and 60kV are available. Other Voltages can be considered.
Power range from 6 kW to 120 kW.
Mains voltage
3 x 400V ± 10% 50-60Hz + Earth
Other values can be considered
Polarity:
Negative (Earth reference)
Voltage regulation
Load variation: better than ± 0.1 % of full voltage (for 10 to 100 % load)
Line regulation: better than ± 0.05 % of full load (for a ± 10% variation of mains voltage)
Current regulation
Load variation: better than ± 0.5 % of full voltage (for 10 to 100 % load)
Line regulation: better than ± 0.05 % of full load (for a ± 10% variation of mains voltage)
Ripple + Noise: less than 0.1% RMS of full voltage
Stored energy: 1 J/ kW
Stability (after one hour warm-up)
0.1 % after 8 hours of operating with constant load and ambient temperature
Temperature coefficient: 200 ppm/°C
Operating temperature: from 0 to 40°C
Stocking temperature: -20 to + 60°C
CE Certification
Adjustable output voltage | Adjustable output current | Efficiency | Stored energy | Size | Weight | |
6 kW | 0 to 60 kV | 0 to 110 mA | > 90% | < 6 Joules | 7U 19" rack – 600 mm depth | 70 kg |
15 kW | 0 to 60 kV | 0 to 260 mA | > 90% | < 15 Joules | 12U 19" cabinet – 800 mm depth | 150 kg |
20 kW | 0 to 60 kV | 0 to 340 mA | > 92% | < 20 Joules | 12U 19" cabinet – 800 mm depth | 160 kg |
40 kW | 0 to 60 kV | 0 to 680 mA | > 92% | < 40 Joules | 24U 19" cabinet – 800 mm depth | 300 kg |
60 kW | 0 to 60 kV | 0 to 1.05 A | > 92% | < 60 Joules | 36U 19" cabinet – 800 mm depth | 380 kg |
80 kW | 0 to 60 kV | 0 to 1.34 A | > 92% | < 80 Joules | 42U 19" cabinet – 800 mm depth | 500 kg |
6 kW | 15 and 20 kW | 40 kW | 60 kW | 80 kW |
![]() |
![]() |
![]() |
![]() |
![]() |
P1: Adjustment of Trs: High Voltage Raising Time when starting.
Min and max times are customer defined. Typically adjustable from 0.2 to 2s.
P2: Adjustment of Tstop: HV stop time following an electric arc.
Min and max times are customer defined. Typically adjustable from 2 to 100ms.
P3: Adjustment of Tra: HV Raising time following a stop due to an electrical arc.
Min and max times are customer defined. Typically adjustable from 5 to 125ms.